1800 655 860
Your SMART Partner
Get in Touch
  • About Us
    • About Us
    • Testimonials
    • News & Events
    • Customer Feedback
    • Product User Guides
  • Services
    • Service & Calibration
    • Legal for Trade
    • Consulting Services
    • SmartTech Software Solutions
    • Service Locations
      • Brisbane
      • Townsville
      • Perth
      • Sydney
      • Melbourne
  • Industries
  • Products / Solutions
    • On-Board Weighing Scales
    • Waste Efficiency Scales
    • Air Safety & Compliance
    • AI Proximity Safety
    • Machine Control Height & Slew
    • Wireless Connectivity Networks
    • Automatic Lubrication Systems
      • Lincoln Dual Line System
      • Lincoln Quicklub System
      • Lincoln Centromatic Systems
    • OnBoard Truck Scales
  • Contact
  • Shop
  • About Us
    • About Us
    • Testimonials
    • News & Events
    • Customer Feedback
    • Product User Guides
  • Services
    • Service & Calibration
    • Legal for Trade
    • Consulting Services
    • SmartTech Software Solutions
    • Service Locations
      • Brisbane
      • Townsville
      • Perth
      • Sydney
      • Melbourne
  • Industries
  • Products / Solutions
    • On-Board Weighing Scales
    • Waste Efficiency Scales
    • Air Safety & Compliance
    • AI Proximity Safety
    • Machine Control Height & Slew
    • Wireless Connectivity Networks
    • Automatic Lubrication Systems
      • Lincoln Dual Line System
      • Lincoln Quicklub System
      • Lincoln Centromatic Systems
    • OnBoard Truck Scales
  • Contact
  • Shop

Clean Air for Mine Crib Rooms and Control Rooms

  • Air Safety & Filtration
8

Do crib rooms and control rooms need air filtration?

Yes, when they sit near crushing, drilling, blasting or diesel equipment. Workers in these rooms breathe the same contaminated air as operators outside, often without respiratory protection. Positive pressure HEPA filtration keeps dust and diesel particulate out, and helps keep rooms within the new national exposure limits.

Most air quality work on mines and quarries focuses on the machine cab. Crib rooms, control rooms, switch rooms and offices often sit just as close to the dust and diesel, yet receive far less attention.

This guide explains why fixed spaces need engineered clean air and what effective protection looks like. Fixed spaces are one part of the operator safety controls we cover in our Protect pillar.

Key takeaways

  • Fixed spaces share the same air as nearby crushing, drilling and diesel plant.
  • Respirators usually come off in crib rooms, so engineering controls matter more.
  • Positive pressure keeps unfiltered air out through gaps and doors.
  • Exposure limits apply to the whole workplace, not only the cab.
Fixed space air quality

Protect the air in your crib rooms

Talk to our team about filtration and positive pressure for crib rooms, control rooms and other fixed spaces on your operation.

No obligation, just a real conversation about what you need.


Why fixed spaces carry real risk

Crib rooms and control rooms go by many names, from smoko rooms and crib huts to switch rooms and welfare units. They share one thing. They sit close to active operations where crushing, drilling, blasting and diesel equipment put contaminants into the air all shift.

A room with a door left open, gaps around cable entries or an ageing air conditioner on recirculation is not a clean air environment. Workers taking a break or monitoring the plant usually remove their respirators there, so whatever enters the room reaches their lungs.

The contaminants that get in

  • Respirable crystalline silica from crushing, screening and haul roads. Its exposure limit is unchanged at 0.05 mg/m3, as our silica limit article explains.
  • Diesel particulate matter from nearby plant and vehicles, which now has its own national limit measured as elemental carbon. Our diesel limit guide covers the state transitions.
  • General dust and fumes carried in on clothing and through doors.

How positive pressure filtration protects a room

A positive pressure system draws outside air through HEPA filtration and supplies more clean air than leaks out. The room sits slightly above outside pressure, so air flows out through gaps rather than in. Adding activated carbon reduces diesel gases and odours that HEPA media cannot capture.

BMair’s F33 and F33-R units are designed for this job in fixed spaces. They supply filtered, pressurised air to rooms of different sizes, with the F33-R suited to installations where recirculated air also needs filtering. The same principles apply as in a cab, which our guide to cab pressurisation explains in more detail.

What good looks like

  • Sealed openings: cable entries, vents and door seals checked and maintained.
  • Positive pressure confirmed by measurement, not assumed.
  • HEPA filtration on incoming air, with carbon where diesel is present.
  • A maintenance schedule for filters and seals, recorded like any other control.
  • Air monitoring to show the room stays within exposure limits.

Exposure limits cover every workspace

Safe Work Australia’s workplace exposure limits apply wherever workers breathe the air, not only inside machines. From 1 December 2026 they replace the old exposure standards, with some states transitioning later, as WorkSafe Queensland and others set out. Our summary of every WEL change has the full picture, and how to pick a cab filter covers the mobile side.

If you need to justify the spend, our cab air business case framework applies equally to fixed spaces.

Frequently asked questions

Straight answers to the questions we are asked most.

Not on its own. Standard air conditioners usually recirculate air with low grade filters and do not pressurise the room, so dust still enters through gaps and doors.

Both supply filtered, pressurised air to fixed spaces. The F33-R is suited to installations where recirculated room air also needs filtering, while the F33 focuses on supplying clean outside air.

Yes. Workplace exposure limits apply to any place where workers breathe the air at work, including crib rooms, control rooms and offices.


Give workers clean air everywhere they work

Protection should not stop at the cab door. Seal fixed spaces, pressurise them with filtered air, maintain the system and measure the result, so workers breathe clean air on breaks and in control rooms too. Our silicosis prevention guide shows how fixed space filtration fits a wider dust control plan.

Contact STA today
Anthony Laverty, Marketing Specialist at SmartTech Australia
Written by

Anthony Laverty

Marketing Specialist, SmartTech Australia

Anthony works alongside SmartTech Australia’s field technicians and product specialists to explain the technology fitted to mining, quarrying, civil and waste fleets across Australia, from payload weighing and cab air filtration to proximity detection and site networks. Before joining STA he served six years in the Australian Army, including operational deployments.

Share this article

Previous Blogs

How Often Should Cab Air Filters Be Changed?

November 10, 2026
Read More

Excavator Pin and Bushing Wear From Poor Greasing

November 10, 2026
Read More

Talk to an expert

Ready for Smarter
Tech on Site?

Get in touch today and let's find the right solution for your operation.

1800 655 860

This form is global for the website

Brisbane

45–47 Bell Are Avenue,
Northgate, QLD 4013

Townsville

11–13 Casey Street,
Townsville, QLD

Sydney

34 Woodfield Blvd,
Caringbah, NSW 2229

Melbourne

11B The Crossway,
Campbellfield, VIC 3061

Perth

2/30 Walters Drive,
Osborne Park, WA 6017
SmartTech Australia logo

Solutions

  • Industrial On-Board Weighing Scales
  • Waste Efficiency Scales
  • Air Safety & Compliance
  • AI Proximity Safety
  • Automated Lubrication
  • Machine Control & Slew
  • Network Connectivity
  • Truck Scales

Services

  • Servicing & Calibration
  • Consulting & Reporting
  • Software Solutions
  • Legal for Trade

Company

  • About Us
  • News & Events
  • User Guides
  • Contact Us

© 2026 SmartTech Australia Sitech WA Pty Ltd. All rights reserved.

Terms & Conditions Policies User Guides