Do crib rooms and control rooms need air filtration?
Yes, when they sit near crushing, drilling, blasting or diesel equipment. Workers in these rooms breathe the same contaminated air as operators outside, often without respiratory protection. Positive pressure HEPA filtration keeps dust and diesel particulate out, and helps keep rooms within the new national exposure limits.
Most air quality work on mines and quarries focuses on the machine cab. Crib rooms, control rooms, switch rooms and offices often sit just as close to the dust and diesel, yet receive far less attention.
This guide explains why fixed spaces need engineered clean air and what effective protection looks like. Fixed spaces are one part of the operator safety controls we cover in our Protect pillar.
Key takeaways
- Fixed spaces share the same air as nearby crushing, drilling and diesel plant.
- Respirators usually come off in crib rooms, so engineering controls matter more.
- Positive pressure keeps unfiltered air out through gaps and doors.
- Exposure limits apply to the whole workplace, not only the cab.
Fixed space air quality
Protect the air in your crib rooms
Talk to our team about filtration and positive pressure for crib rooms, control rooms and other fixed spaces on your operation.
No obligation, just a real conversation about what you need.
Why fixed spaces carry real risk
Crib rooms and control rooms go by many names, from smoko rooms and crib huts to switch rooms and welfare units. They share one thing. They sit close to active operations where crushing, drilling, blasting and diesel equipment put contaminants into the air all shift.
A room with a door left open, gaps around cable entries or an ageing air conditioner on recirculation is not a clean air environment. Workers taking a break or monitoring the plant usually remove their respirators there, so whatever enters the room reaches their lungs.
The contaminants that get in
- Respirable crystalline silica from crushing, screening and haul roads. Its exposure limit is unchanged at 0.05 mg/m3, as our silica limit article explains.
- Diesel particulate matter from nearby plant and vehicles, which now has its own national limit measured as elemental carbon. Our diesel limit guide covers the state transitions.
- General dust and fumes carried in on clothing and through doors.
How positive pressure filtration protects a room
A positive pressure system draws outside air through HEPA filtration and supplies more clean air than leaks out. The room sits slightly above outside pressure, so air flows out through gaps rather than in. Adding activated carbon reduces diesel gases and odours that HEPA media cannot capture.
BMair’s F33 and F33-R units are designed for this job in fixed spaces. They supply filtered, pressurised air to rooms of different sizes, with the F33-R suited to installations where recirculated air also needs filtering. The same principles apply as in a cab, which our guide to cab pressurisation explains in more detail.
What good looks like
- Sealed openings: cable entries, vents and door seals checked and maintained.
- Positive pressure confirmed by measurement, not assumed.
- HEPA filtration on incoming air, with carbon where diesel is present.
- A maintenance schedule for filters and seals, recorded like any other control.
- Air monitoring to show the room stays within exposure limits.
Exposure limits cover every workspace
Safe Work Australia’s workplace exposure limits apply wherever workers breathe the air, not only inside machines. From 1 December 2026 they replace the old exposure standards, with some states transitioning later, as WorkSafe Queensland and others set out. Our summary of every WEL change has the full picture, and how to pick a cab filter covers the mobile side.
If you need to justify the spend, our cab air business case framework applies equally to fixed spaces.
Not on its own. Standard air conditioners usually recirculate air with low grade filters and do not pressurise the room, so dust still enters through gaps and doors.
Both supply filtered, pressurised air to fixed spaces. The F33-R is suited to installations where recirculated room air also needs filtering, while the F33 focuses on supplying clean outside air.
Yes. Workplace exposure limits apply to any place where workers breathe the air at work, including crib rooms, control rooms and offices.
Give workers clean air everywhere they work
Protection should not stop at the cab door. Seal fixed spaces, pressurise them with filtered air, maintain the system and measure the result, so workers breathe clean air on breaks and in control rooms too. Our silicosis prevention guide shows how fixed space filtration fits a wider dust control plan.
Contact STA today
Written by
Anthony Laverty
Marketing Specialist, SmartTech Australia
Anthony works alongside SmartTech Australia’s field technicians and product specialists to explain the technology fitted to mining, quarrying, civil and waste fleets across Australia, from payload weighing and cab air filtration to proximity detection and site networks. Before joining STA he served six years in the Australian Army, including operational deployments.