Your SMART Partner
BMair F33-R Rooftop Cabin Air Filtration, Mines and Heavy Industry | SmartTech Australia
Home › BMair Cabin Air Filtration › BMair F33-R
BMair Range

BMair F33-R

Full-capacity rooftop HEPA filtration. Heavy machines and fixed site spaces. Seven filter combinations.

The BMair F33-R is the rooftop solution for heavy machines and fixed site spaces where deck or fender space is insufficient for a conventional cabin air filtration system. Rather than compromise on filtration capacity, BMair engineers developed the F33-R to deliver the same high-performance HEPA P1/P3 protection as the MAO-3C in a flat, low-profile unit at just 235 mm height. When the deck is cluttered with components, hydraulic lines, or toolboxes, the F33-R goes on the roof.

Equally suited to fixed spaces on site, the F33-R can be installed in mine site control rooms, crib rooms, site offices, and portable buildings that sit adjacent to high-dust operations. Wherever people work or rest in contaminated environments, the F33-R provides positive pressure HEPA protection. It supports seven filter combinations and includes the F4000 Smart Control with touchscreen, 4G connectivity, real-time pressure monitoring, and integrated data logging.

Key Specifications
Dimensions
715 × 665 × 235 mm
Mounting
Rooftop, flat horizontal
Dust Filtration
P1/P3 H13 HEPA
Filter Combinations
7 options
Primary Use
Machines and fixed spaces
Connectivity
F4000 Smart Control
🇦🇺 Exclusive Australian Distributor of BMair Systems
FAQs
Dimensions715 × 665 × 235 mm (L × W × H)
Profile Height235 mm, flat rooftop low-profile design
MountingRooftop, flat horizontal installation
Dust FiltrationP1/P3 H13 HEPA (ISO 29463)
Filtration EfficiencyGreater than 99.95% at most penetrating particle size
Gas FiltrationSix activated carbon combinations available
Filter Combinations7 total (dust only + 6 carbon options)
ControllerF4000 Smart Control (touchscreen, 4G, data logging)
MonitoringReal-time cabin pressure monitoring, air quality sensor
ComplianceISO 23875
Primary ApplicationHeavy machines and fixed site spaces (control rooms, crib rooms, site offices)
Full-Capacity Rooftop DesignDelivers the same high-performance HEPA P1/P3 filtration as a deck-mounted system when deck or fender space is insufficient. No compromise on protection.
Low 235mm ProfileFlat horizontal rooftop unit at only 235 mm height minimises wind resistance, maintains cab clearance, and fits a wide range of truck configurations
Seven Filter CombinationsDust-only through to full ABEK, dredger, and mercury-grade protection. All filter combinations replaced tool-free with RFID auto-logging on change-out
F4000 Smart ControlTouchscreen controller with 4G connectivity, integrated data logging, air quality sensor, maintenance messages with QR code generator, and automatic or manual mode selection
Real-Time MonitoringContinuous cabin pressure monitoring with immediate warnings for pressure loss or other hazards. Air quality sensors available as plug-and-play additions
Fixed Space ApplicationsSuitable for mine site control rooms, crib rooms, site offices, and portable buildings on high-dust operations, in addition to heavy machine cab installations
Asbestos / DustP1-P3/H13. Protects against silica dust, asbestos, toxic particulate matter, and heavy metals. Efficiency greater than 99.95%
Benzene (A)P1-P3/H13-A. Vapours from solvents and hydrocarbons including diesel fumes
Ammonia / Organic Waste (AK)P1-P3/H13-A-K. Vapours from waste and composting including spores, bacteria, viruses, organic matter, and ammonia
ABEKP1-P3/H13-ABEK. Mixed toxic vapours in accordance with EN14387
ABE/KP1-P3/H13-ABE-K. H2S and ammonia (not for use with cyanides such as HCN)
Dredging (ABE)P1-P3/H13-ABE. Dredging spoil vapours including bacteria, toxic particulate matter, heavy metals, and H2S
AXP1-P3/H13-A-AX. Solvents and hydrocarbons with boiling point below 65°C
Suited for

Mining, Quarry, Civil Construction, Waste and Recycling, Demolition, Composting, Land Remediation, Dredging, Heavy Industry, Rail and Ports, and more. Also suited for control rooms, crib rooms, site offices, and portable buildings on high-dust sites.

How It Works

Rooftop Protection. Full Capacity. No Compromises.

The F33-R installs flat on the roof or wall of any space requiring clean filtered air, delivering the same high-capacity HEPA protection as a deck-mounted system without needing deck or fender space. Three stages work continuously to keep the space clean and positively pressurised.

1
Rooftop Air Intake

Contaminated external air is drawn into the F33-R unit mounted flat on the cabin roof. The rooftop position draws air from above the vehicle, away from road-level dust, exhaust sources, and deck contamination. This improves the quality of air entering the filtration stage before it is processed.

2
HEPA and Carbon Filtration

Air passes through the P1/P3 H13 HEPA stage, capturing fine dust, silica, asbestos, and hazardous particulates at greater than 99.95% efficiency. When a carbon filter combination is installed, gases and vapours are removed in a separate sealed stage. Seven combinations are available to match the exact contamination profile of the site, from dust-only through to full ABEK or dredger-grade protection.

3
Positive Pressure and F4000 Monitoring

Clean filtered air is delivered at positive pressure, preventing contaminated air entering through gaps and seals. The F4000 Smart Control monitors pressure in real time via its touchscreen and built-in air quality sensor, issuing immediate warnings for pressure loss or gas detection. Data logging with 4G connectivity and maintenance alerts with QR code generation are included as standard.

Applications

Industries and Applications

The F33-R protects operators in heavy machine cabs and workers in fixed site spaces. Use the fit checker to confirm compatibility with your machine or building.

Industries
Mining Quarry & Aggregate Civil Construction Waste & Recycling Demolition Composting Land Remediation Dredging Heavy Industry Rail and Ports Road Construction Tunnelling
Machines and Spaces
Haul Trucks Excavators Wheel Loaders Bulldozers Graders Material Handlers Drill Rigs Compactors Control Rooms Crib Rooms Site Offices Portable Buildings
Machine and Space Checker

Select your machine or space type to check compatibility with the BMair F33-R.

Frequently Asked Questions

BMair F33-R

Answers about the F33-R rooftop design, machine and space compatibility, filter options, F4000 Smart Control, and ISO 23875 compliance.

The F33-R is designed for two distinct applications. For heavy machines operating on mining, quarry, civil construction, waste, and demolition sites where the deck is cluttered with components, hydraulic lines, or toolboxes leaving no deck or fender space for a conventional unit, the F33-R mounts flat on the cabin roof at just 235 mm height to deliver full-capacity HEPA P1/P3 filtration. Primary machines include haul trucks, excavators, wheel loaders, graders, material handlers, and drill rigs.

The F33-R is also purpose-suited to fixed spaces on site. Mine site control rooms, crib rooms, crib huts, site offices, and portable buildings that sit adjacent to high-dust operations are all valid applications. Workers in these spaces spend concentrated time at rest or monitoring, often in buildings positioned close to the contamination source. Positive pressure HEPA filtration in these spaces is a direct WHS obligation under Australian silica dust regulations. SmartTech Australia can assess your specific machine or space and confirm the right installation approach.

Read more: Silicosis Safety: Protecting Workers from Harmful Dust  |  BMair Cabin Air Filtration Range

Both the F33-R and the MAO-3C Cab Guard deliver the same high-performance HEPA P1/P3 filtration and support identical filter combinations. The difference is mounting position and controller. The MAO-3C is designed for horizontal deck or fender mounting, is self-cleaning, and uses BMair Connect for RFID filter tracking and compliance logging (note: BMair Connect is specific to the Protector range and MAO-3C). The F33-R mounts flat on the cabin roof at 235 mm height and uses the F4000 Smart Control with touchscreen, 4G, and integrated data logging.

When deck or fender space is available, the MAO-3C is often the preferred choice for heavy machines due to its self-cleaning filter. When deck space is cluttered or unavailable, the F33-R delivers equivalent protection from the rooftop. The F33-R also opens up applications the MAO-3C is not designed for, including fixed site spaces such as control rooms and crib rooms. If you are unsure which system suits your situation, contact SmartTech Australia for a no-obligation assessment.

The F33-R supports seven filter combinations covering the full range of dust and gas hazards encountered on Australian heavy vehicle worksites:

  • Asbestos / Dust (P1-P3/H13): HEPA particulate only. Protects against silica dust, asbestos, toxic particulate matter, and heavy metals. Efficiency greater than 99.95%.
  • Benzene (P1-P3/H13-A): HEPA plus Carbon A. Vapours from solvents and hydrocarbons including diesel fumes.
  • Ammonia / Organic Waste (P1-P3/H13-A-K): HEPA plus Carbon AK. Waste and composting environments including spores, bacteria, viruses, organic matter, and ammonia.
  • ABEK (P1-P3/H13-ABEK): HEPA plus Carbon ABEK. Mixed toxic vapours in accordance with EN14387.
  • ABE/K (P1-P3/H13-ABE-K): HEPA plus Carbon ABEK. H2S and ammonia (not for use with cyanides such as HCN).
  • Dredging (P1-P3/H13-ABE): HEPA plus Carbon ABE. Dredging spoil vapours including bacteria, toxic particulate matter, heavy metals, and H2S.
  • AX (P1-P3/H13-A-AX): HEPA plus Carbon AX. Solvents and hydrocarbons with boiling point below 65°C.

SmartTech Australia can confirm the right filter combination for your specific worksite and contamination profile. SmartTech Australia can confirm the right combination for your site.

Yes. The F33-R meets the requirements of ISO 23875, the international standard for operator enclosure pressurisation and air quality on earth-moving and heavy machinery. When connected to BMair Connect, it supports compliance with the Australian RS20 mining standard. ISO 23875 requires HEPA-grade filtration, positive pressure above 50 Pa, and real-time pressure monitoring, all of which the F33-R delivers as a complete system.

Australia's Work Health and Safety regulations require operators and workers in silica dust environments to be protected from exposure exceeding 0.05 mg/m³ averaged over an eight-hour shift. This applies both to machine operators and to workers in fixed site spaces such as crib rooms and site offices in proximity to high-dust operations. The F4000 Smart Control provides the real-time monitoring and integrated data logging required to demonstrate that protection is operating effectively.

Read more: ISO 23875 Air Quality Standards in Australia  |  Is Your Mining Vehicle's Cabin Air Filter Protecting Operators Effectively?

The F33-R includes the F4000 Smart Control as standard. The F4000 is a dedicated cabin pressure and air quality monitor with a full touchscreen interface. Key features include real-time cabin pressure monitoring with immediate warnings for pressure loss or gas detection, 4G connectivity for wide data access, integrated data logging for compliance records, maintenance messages with a QR code generator for filter service, and a high-quality sensitivity air quality sensor. The mode can be switched between automatic, manual, and stand-by with two clicks.

For environments where carbon filters are installed, plug-and-play air quality sensors are available as additions to the F4000. These include VOC, NH3, and CO2 sensors depending on the contamination profile of the site. Contact SmartTech Australia to confirm the right sensor configuration for your application.

Yes. The dust-only Asbestos/P1-P3/H13 configuration suits quarry, mining, and construction sites where fine particulate is the primary hazard. For sites with both dust and gas or vapour hazards, the F33-R supports six activated carbon filter combinations that handle both in a single pass. This is particularly relevant for fixed site spaces like crib rooms or control rooms near waste, composting, or remediation operations, as well as machines operating in mixed-hazard environments.

Common applications with gas and vapour hazards include waste and recycling operations (ammonia, H2S, organic vapours), contaminated demolition and remediation sites (solvents, VOCs), dredging operations (H2S, bacteria, heavy metals), and bitumen and asphalt paving (PAHs, hydrocarbon fumes). The carbon filter combination can be selected to match the specific hazard profile of the site and changed when the machine or building moves to a different application. SmartTech Australia can advise on the correct carbon specification for your situation.