What is the best cabin air filter for heavy equipment?
The best system filters both fresh and recirculated air through HEPA media, adds activated carbon where diesel exhaust is present, and keeps the cab at positive pressure. ISO 23875 sets the benchmark of at least 20 Pa above outside air, carbon dioxide held near ambient, and continuous monitoring that proves it is working.
Operators in mining, quarrying, tunnelling and civil construction spend whole shifts in a cab surrounded by silica dust, diesel exhaust and other contaminants. The filter grade printed on a box tells you only part of the story.
This guide explains what makes a cab filtration system effective, how ISO 23875 defines good performance, and the questions to ask before you choose. For the wider context, see how filtration fits our operator protection framework.
Key takeaways
- Filter both air paths. Fresh air and recirculated air both need HEPA filtration.
- HEPA does not stop gases. Diesel exhaust needs an activated carbon stage.
- Pressure keeps dust out. ISO 23875 requires at least 20 Pa above outside air.
- Monitoring proves it works, shift by shift rather than on install day only.
Cab air quality
Check how your cabs measure up
Talk to our team about cab filtration, pressurisation testing and ISO 23875 monitoring for your fleet.
No obligation, just a real conversation about what you need.
What a complete cab filtration system includes
Cab filtration systems generally fall into two designs. An open circuit system filters incoming fresh air but leaves recirculated air to the machine’s standard HVAC filter, which is rarely designed for respirable dust. A closed circuit system filters both paths through HEPA media and keeps the cab pressurised so dusty outside air has no path in around door rubbers or panel joins.
- HEPA filtration on fresh and recirculated air. HEPA H13 media captures at least 99.95 percent of particles at the most penetrating particle size.
- Activated carbon where diesel exhaust, vapours or odours are present, because HEPA media does not capture gases.
- Positive pressure to keep unfiltered air out.
- Monitoring and alarms for pressure and carbon dioxide, so the operator knows when performance drops.
What ISO 23875 actually requires
ISO 23875 is the international standard for operator cab air quality control on mobile machinery. It covers the whole system rather than the filter alone.
| Requirement | ISO 23875 benchmark |
| Cab pressure | At least 20 Pa above outside air, with a 200 Pa upper limit |
| Carbon dioxide | Held within 400 ppm of the outside level |
| Monitoring | Continuous, with an operator warning when limits are not met |
| Testing | Performance tested at installation and maintained over time |
Our guide to cab pressurisation explains why pressure matters as much as filtration.
Matching the filter to the contaminant
- Respirable crystalline silica in quarries and tunnelling calls for HEPA filtration on both air paths. The regulatory side is set out in our silica deadline article.
- Diesel particulate matter needs HEPA for the particles and carbon for the gas phase. The new national DPM limit is explained in our diesel limit guide.
- Vapours and odours from chemicals, waste or bitumen need a carbon stage sized for the job.
Questions to ask before you choose
- Does the system filter recirculated air through HEPA, or only fresh air?
- Is there a carbon stage, and is it suited to diesel exhaust?
- Will the cab reach and hold at least 20 Pa, and how is that tested?
- Does the operator see pressure and carbon dioxide readings in real time?
- Who will maintain filters and seals, and how often?
Filters only perform when they are fitted and changed correctly. The South Australian mining and quarrying safety committee’s cabin maintenance guidance is a useful reference for inspection routines.
Where this fits with exposure limits
The new national workplace exposure limits start applying on the first of December this year, though several states phase them in later. Engineering controls such as cab filtration sit above respirators in the hierarchy of controls. Our summary of every WEL change covers the detail, and our cab air business case guide helps you secure budget.
ISO 23875 requires the cab to be held at a minimum of 20 Pa above outside air, with an upper limit of 200 Pa, and pressure must be monitored continuously.
HEPA media captures diesel particles but not the gas phase of the exhaust. An activated carbon stage is needed to reduce diesel gases and odours.
HEPA filtration on both the fresh and recirculated air paths, combined with positive cab pressure, gives the best protection against respirable crystalline silica in a quarry.
A sealed, pressurised cab can build up carbon dioxide from the operator’s breathing if fresh air supply is too low. ISO 23875 limits it to 400 ppm above outside air to keep operators alert.
Choose the system, not just the filter
The best cabin air filter is part of a system that filters both air paths, handles gases where needed, holds positive pressure and proves its performance every shift. Measure your options against ISO 23875 and keep up the maintenance. Fixed spaces need the same care, as our guide to clean air for crib rooms explains.
Contact STA today
Written by
Anthony Laverty
Marketing Specialist, SmartTech Australia
Anthony works alongside SmartTech Australia’s field technicians and product specialists to explain the technology fitted to mining, quarrying, civil and waste fleets across Australia, from payload weighing and cab air filtration to proximity detection and site networks. Before joining STA he served six years in the Australian Army, including operational deployments.