Does the silica exposure limit change on 1 December 2026?
No. Respirable crystalline silica stays at 0.05 mg/m3 as an 8 hour time weighted average from 1 December 2026. Silica is one of nine chemicals that work health and safety ministers held at current levels for further work, so its limit carries across unchanged into the new Workplace Exposure Limits list.
Plenty of businesses expected silica to be the headline of the 2026 change. It isn’t. The number stays the same, while limits for diesel, cement dust and exhaust gases fall around it, as our full table of WEL changes shows.
That makes silica easy to misread in both directions. Some assume nothing needs doing, and others assume the limit has been cut. Neither is right, and this page sets out what actually applies.
Key takeaways
- The number holds. Silica stays at 0.05 mg/m3 as an 8 hour TWA under the WEL list.
- Nine chemicals were held back. Ministers kept silica, benzene, formaldehyde, nitrogen dioxide and five others at current levels.
- Your duties do not pause. Exposure must still be minimised so far as reasonably practicable, with health monitoring where required.
- Silica control is not diesel control. A cab that handles silica can still fail the new diesel and gas limits.
Silica, diesel and gases
Check your cabs against every limit, not just silica
Book a demo and we will show you how a pressurised HEPA cab controls silica dust and how carbon filtration covers the diesel side as well.
No obligation, just a real conversation about what you need.
Why the silica limit was held
When work health and safety ministers agreed the new list, they could not settle nine chemicals and asked for further work on them. Safe Work Australia has since published its decision on those nine chemicals, confirming they keep their current values from 1 December 2026.
- Respirable crystalline silica
- Benzene, chlorine, copper and formaldehyde
- Hydrogen cyanide and hydrogen sulphide
- Nitrogen dioxide and titanium dioxide
Earlier versions of this page said these nine became enforceable at new levels on 1 December. That was wrong, and the page has been corrected.
What still applies to silica
A held limit is not a relaxed one. From 1 December 2026, 0.05 mg/m3 is a Workplace Exposure Limit on the national list, and the existing duties around it continue.
- Keep pushing exposure down. Sitting under 0.05 mg/m3 does not end the duty, because exposure still has to be reduced as far as is reasonably practicable.
- Air monitoring. Where you are unsure whether exposure exceeds the limit, monitoring is how you find out.
- Health monitoring. The model WHS regulations list crystalline silica among the substances that need health monitoring where there is a significant risk to health.
Silica is also why Safe Work Australia’s airborne contaminants guidance keeps the hierarchy of controls front and centre, with engineering controls ahead of respirators.
Why meeting the silica limit is not the whole picture
The machines raising silica dust at the face, the crusher or the stockpile are almost always diesel. From 1 December 2026, diesel particulate matter has its own limit, nitric oxide falls from 25 ppm to 2 ppm and sulfur dioxide from 2 ppm to 0.25 ppm. A cab that keeps silica out with HEPA filtration alone can still let the exhaust gases in.
Quarries feel this most, because crushing, screening and load and haul put silica and diesel in the same air all day. Our page on what the WEL changes mean for quarries works through it stage by stage.
Keeping silica out of the operator’s breathing zone
The controls that work for silica have not changed, but how well they are maintained is what an inspector will look at.
- Stop it at the source. Water sprays and suppression on drills, crushers, screens and haul roads keep dust from becoming airborne.
- Hold the cab at positive pressure. Cab pressurisation with HEPA filtration keeps outside dust from leaking in through seals and gaps. The BMair Protector was designed to the ISO 23875 cab air standard to do this job.
- Treat fixed spaces the same way. Crib rooms and control rooms sit beside the same dust sources as the machines.
- Keep respirators as the last line. They depend on fit and correct use every shift, so they back up engineering controls rather than replace them.
For the health side of silica exposure, our page on preventing silicosis goes further, and the ISO 23875 standard explains what a compliant cab air system has to do.
No. The figure for respirable crystalline silica is still 0.05 mg/m3 averaged over an 8 hour shift, because silica was one of the nine chemicals left at its existing value when the WEL list was agreed.
Respirable crystalline silica, benzene, chlorine, copper, formaldehyde, hydrogen cyanide, hydrogen sulphide, nitrogen dioxide and titanium dioxide. Each carries its existing value across into the Workplace Exposure Limits list from 1 December 2026.
Yes. The model WHS regulations list crystalline silica among the hazardous chemicals that require health monitoring where workers face a significant risk to health from exposure. The 2026 change does not remove that requirement.
Not by itself. The diesel, nitric oxide and sulfur dioxide limits all tighten on 1 December 2026, and a HEPA system tuned for silica leaves exhaust gases untouched, so test the cab against those limits too.
Silica holds steady while the limits around it fall
The silica number is not moving, but the air in a cab is never only silica. Keep your silica controls maintained and recorded, then check the same cabs against the diesel and gas limits that do change. Our guide to protecting heavy equipment operators sets out the controls for dust, diesel and blind spots together.
Contact STA today
Written by
Anthony Laverty
Marketing Specialist, SmartTech Australia
Anthony works alongside SmartTech Australia’s field technicians and product specialists to explain the technology fitted to mining, quarrying, civil and waste fleets across Australia, from payload weighing and cab air filtration to proximity detection and site networks. Before joining STA he served six years in the Australian Army, including operational deployments.