What is the diesel particulate matter exposure limit in Australia?
From 1 December 2026, the national Workplace Exposure Limit for diesel particulate matter is 0.01 mg/m3, measured as respirable elemental carbon over an 8 hour shift. Victoria keeps 0.1 mg/m3 until December 2029, and Queensland’s regulator lists the same transition. Controlling diesel exhaust needs HEPA filtration for particles and activated carbon for gases.
Silica has dominated the air quality conversation in mines and quarries, but the same fleets also run on diesel, and diesel exhaust now has a national limit of its own. It is one of the changes covered in our full table of 2026 exposure limit changes.
Diesel also behaves differently from dust in a way that decides how you control it. It is a fine particulate and a mix of gases at the same time, so a filter designed only for dust stops part of it and lets the rest through.
Key takeaways
- A first national limit. Diesel particulate matter is listed at 0.01 mg/m3 as respirable elemental carbon, applying beyond mining for the first time.
- Not every state starts on the same day. Victoria holds diesel at 0.1 mg/m3 until 1 December 2029, and Queensland’s regulator lists the same figure.
- Diesel exhaust is a Group 1 carcinogen. The International Agency for Research on Cancer classified it in 2012.
- Dust filters do half the job. HEPA captures the particles, and activated carbon is needed for the gas phase.
Diesel and dust in one system
Find out what your cabs need for diesel
Book a demo and we will show you how HEPA and activated carbon work together in a pressurised cab, and the record it keeps for every shift.
No obligation, just a real conversation about what you need.
A first national limit, not simply a lower one
Until now there was no national exposure standard for diesel particulate matter in general industry. Some mining jurisdictions set their own figure: NSW introduced 0.1 mg/m3 for its mines in 2021, measured as sub-micron elemental carbon, and Western Australia’s mines work to the same number.
The new national figure of 0.01 mg/m3 is measured differently, as respirable elemental carbon, so the two numbers are not a straight like-for-like comparison. What is clear is the direction: a much lower limit that now reaches workshops, tunnels, quarries, ports and waste depots, not only mines.
Where the transition periods apply
The WEL list takes effect through each state’s own laws, and diesel is the substance where start dates differ most. As of November 2026:
| Jurisdiction | From 1 Dec 2026 | Lower limit applies |
| National WEL list | 0.01 mg/m3 | 1 Dec 2026 |
| Victoria, underground mining | 0.1 mg/m3 | Stays at 0.1 mg/m3 |
| Victoria, all other industries | 0.1 mg/m3 | 0.01 mg/m3 from 1 Dec 2029 |
| Queensland | 0.1 mg/m3 | Transition to 1 Dec 2029 |
The Victorian figures come from WorkSafe Victoria’s WEL FAQs, and the Queensland figure from WorkSafe Queensland’s FAQs. Our Victorian WEL guide covers the full transition list. Check your own regulator before you plan around a date, because these arrangements are still being settled.
Who is most exposed to diesel exhaust
Exposure is highest wherever exhaust cannot disperse. Underground headings and tunnels trap exhaust from loaders, trucks and support plant in a small volume of air. Surface load and haul, waste depots, ports and enclosed workshops build up their own diesel load across a shift.
In almost every case the most exposed person is the operator, sitting in the exhaust stream of their own machine and the ones working around it. That is why the cab is where control starts.
Why dust filters alone do not stop diesel
Diesel exhaust has two parts. The particulate fraction is elemental and organic carbon, which a HEPA H13 filter captures at 99.95 percent or better. The gas phase is nitrogen oxides, carbon monoxide, sulfur dioxide and volatile organic compounds, and gases pass through HEPA media because they are not particles.
Controlling the gas phase takes activated carbon, which adsorbs gases and vapours rather than straining them out. Both stages only work if the cab is held at positive pressure, because cab pressurisation stops unfiltered air leaking in around doors and seals.
Options for cabs and fixed spaces
- Machine cabs: the BMair Protector Plus X pairs HEPA filtration with an activated carbon module selected for diesel and hydrocarbon vapours.
- Crib rooms, control rooms and site offices: the BMair F33 and F33-R bring the same two-stage approach to fixed spaces, covered in our guide to clean air in crib and control rooms.
- Choosing between systems: our cabin air filter buying guide explains open and closed circuit designs and what ISO 23875 asks for.
Proving the air is clean
Safe Work Australia has published a guide to managing diesel engine emissions that explains how to identify exposure risks and carry out air and health monitoring. Air monitoring by an occupational hygienist tells you where you stand today. A cab system that logs pressure and filter status every shift tells you whether it stays that way, and gives you the record a regulator will ask for.
The national Workplace Exposure Limit is 0.01 mg/m3, measured as respirable elemental carbon over an 8 hour time weighted average. It applies through each state’s work health and safety laws, so check your own regulator, because Victoria and Queensland list a transition at 0.1 mg/m3 until 1 December 2029.
Not straight away. WorkSafe Victoria applies 0.1 mg/m3 from 1 December 2026, moving to 0.01 mg/m3 in December 2029 for all industries except underground mining, which stays at 0.1 mg/m3. WorkSafe Queensland lists 0.1 mg/m3 until 1 December 2029.
Diesel exhaust is a particulate mixed with gases. HEPA H13 media captures 99.95 percent or more of the fine particles, but nitrogen oxides, carbon monoxide and other gases pass through it. Activated carbon is needed to adsorb the gas phase, inside a cab held at positive pressure.
Exposure is measured with personal air sampling on the worker, analysed for respirable elemental carbon and averaged over the shift. An occupational hygienist normally runs the sampling. Older mining standards used sub-micron elemental carbon, which is a different method, so old and new results are not directly comparable.
Diesel is the half of the change dust controls miss
Silica has had the spotlight, but diesel is the part of the 2026 change most likely to catch a fleet out, because the control that works for dust only does half the job. Measure where you stand, fit HEPA and carbon inside a pressurised cab, and keep the record. Start with our guide to protecting heavy equipment operators, or talk to the team about your machines.
Contact STA today
Written by
Anthony Laverty
Marketing Specialist, SmartTech Australia
Anthony works alongside SmartTech Australia’s field technicians and product specialists to explain the technology fitted to mining, quarrying, civil and waste fleets across Australia, from payload weighing and cab air filtration to proximity detection and site networks. Before joining STA he served six years in the Australian Army, including operational deployments.